0.2, which is about 3.5 times that of the substrate. The cladded coating shows significantly better wear resistance than the substrate under different loads with the lower friction coefficient and the less wear amount. In 3.5wt% NaCl solution, the self-corrosion current density of the coating is 4.74 × 10-8A.cm-2, which is two orders of magnitude lower than that of the substrate, showing excellent corrosion resistance. Under the coupling effect of friction load and corrosion, the open circuit potential of the coating shifted negatively and the corrosion tendency increased. With the increase of friction load, the free-corrosion potential moves negatively, the free-corrosion current density increases, and the effect of friction promoting corrosion increases."/>
1.School of Materials Science and engineering;2.School of Materials Science and Engineering
[Cao Chenjie, Wang Yanfang, Zhang Cunxiu, Niu Dewen, Si Yudong, Si Jiajia, Shi Zhiqiang, He Yanling. Tribocorrosion behaviors of laser cladding FeCrNiCoMoCuBSi high entropy alloy coating[J]. Rare Metal Materials and Engineering,2023,52(4):1439~1446.]
DOI:10.12442/j. issn.1002-185X.20220227